7. Configuration
Once all APC panels in the system are correctly cabled, the next step is to configure
the panels for proper operation. Jumpers on the back of each board are used to
select the panel function. See diagram below for jumper locations.
Note: Early hardware release has JP1 (terminate) on the parts side of the board. It is
necessary to remove the processor board from the button board to set termination.
Jumper Function Default state
1 DMX Terminate Open - not terminated
2 Master enable Open - Slave
3 Arch / backup Open - Arch
4 Single Station Open - multiple station
5 Not used Open
6 No DMX when off Open - DMX always on
7 Not used Open